Sign In | Join Free | My chinaqualitycrafts.com |
|
Brand Name : UC
Model Number : UC8201
Place of Origin : CHINA
MOQ : 1pcs
Price : negotiate a price
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram, D/A
Supply Ability : 15pcs+per month
Delivery Time : 15 work days
Packaging Details : Carton
Number of Channels : 1
Wavelength Range : 850 ~ 1700 nm
Power Range : +10 ~ -70dBm/+25 ~ -55dBm
Sampling period : 1ms (1KHz)
Absolute Uncertainty (accuracy) at reference condition : ± 4% (1200 nm ~ 1610 nm)
Relative Uncertainty (accuracy) at reference condition : < 0.02 dB Typical
Operation Temperature : 0~ +40 ℃
Single-channel optical power meter with Power Range +10 ~ -65dBm/+25 ~ -50dBm
Model # | UC8204 | |||
Number of Channels | 4 | |||
Power Range | +10 ~ -70dBm | |||
Wavelength Range | 850 ~ 1700 nm | |||
Calibration Wavelength | 850/908/1270/1290/1310/1330/1510/1530/1550/1570 nm | |||
Sampling period | 1ms (1KHz) | |||
Application Fiber Type | Standard SM and MM up to 62.5 um core size | |||
Absolute Uncertainty (accuracy) at reference condition | ± 4% (1200 nm ~ 1610 nm) | |||
Relative Uncertainty (accuracy) at reference condition | < 0.02 dB Typical | |||
Linearity (power) | ≤ ± 0.05 dB (1200 nm ~ 1610 nm, 0~ -50dBm) | |||
Return Loss | > 40 dB | |||
Operation Temperature | 0 ~ +40℃ | |||
Storage Temperature | -30 ~ +80℃ | |||
Recalibration Period | 2 years | |||
Dimensions | 245 mm W, 105 mm H, 320 mm D | |||
Weight | 2.0 kg |
UC8202/4 optical power meter test systems are efficient, compact sized, fast-starting, and affordable. They provide low power, high power, single channel and dual channel optical power meter options.
UC8202/4 2/4channel optical power meters offer superior performance, economical and practical for general purpose of fiber optical test and measurement applications. It is specifically designed for use in high volume production lines.
Ac Power Supply Requirements
The instrument complies with overvoltage class II regulations. The operating voltage is 100 ~240V AC voltage, frequency range 48-66Hz, operating voltage 115V When, the maximum consumption current is 230mA; Operating voltage 230V, the most
The maximum consumption current is 120mA.
The power cord
According to international safety standards, the instrument is equipped with a 3-core power cord that meets national standards. Only connect the power cord Plug into a power outlet with ground protection.
Power indicator
The power indicator lights up when the instrument is powered on.
Communication Interface Description
There are two communication ports on the back panel of the instrument, namely USB interface and RS232 interface.
The USB interface
USB interface is a standard 4-core B-type interface, which can be connected to the instrument and PC, and the instrument can be controlled by monitoring software.
RS232 serial port
The serial port parameters of the instrument are set to a fixed value. The serial port parameter Settings of the computer must match the instrument parameter Settings.
Fixed parameters:
Baud rate: 115,200
Number of digits: 8
Check: None
Stop number: 1
RS232 interface
![]() |
Single Channel Optical Power Meter With Power Range +10 ~ -65dBm/+25 ~ -50dBm Images |